Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 207
Filter
1.
Arq. bras. oftalmol ; 87(2): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527833

ABSTRACT

ABSTRACT A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.


RESUMO Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.

2.
Arq. bras. oftalmol ; 86(4): 301-307, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447364

ABSTRACT

ABSTRACT Purpose: To evaluate visual outcomes, satisfaction, and quality of life of patients assisted in a Medical School hospital by the Brazilian Public Health System, who underwent bilateral diffractive multifocal intraocular lens implantation. Methods: Case series study with intervention, including 20 patients who underwent bilateral implantation of multifocal IOL EyeDiff® (Eyeol UK, Dunstable, UK). Exclusion criteria were corneal astigmatism >1.5 cylindrical diopters, previous ocular surgery or ocular disease, and intra- or postoperative complications. Patients were evaluated one, three, and six months after surgery. Monocular and binocular visual acuity for distance, intermediate and near, under photopic and mesopic conditions, monocular contrast sensitivity under photopic conditions, defocus curve, and quality of life were assessed. Results: Monocular distance-corrected visual acuity was 0.3 logMAR or better and monocular distance-corrected near visual acuity was J3 or better in all eyes under photopic conditions. Binocular distance-corrected near visual acuity was J1 in all cases. Contrast sensitivity was at the minimum level of normality for low and high spatial frequencies and within normal limits for intermediate spatial frequency. The quality of life questionnaire showed a high level of patient satisfaction. Conclusion: Bilateral implantation of the multifocal intraocular lens EyeDiff® provides patients with good visual acuity and quality of life, besides spectacle independence. The visual acuity and contrast sensitivity progressively improved between one and six postoperative months.


RESUMO Objetivo: Avaliar os resultados visuais, satisfação e qualidade de vida de pacientes atendidos em um hospital escola pelo Sistema Único de Saúde, submetidos a implante bilateral de lente intraocular multifocal difrativa. Métodos: Estudo tipo série de casos com intervenção, incluindo 20 pacientes submetidos a implante bilateral da lente intraocular multifocal difrativa EyeDiff® (Eyeol UK, Dunstable, UK). Os critérios de exclusão foram astigmatismo corneano >1,5 dioptria cilíndrica, cirurgia ou doença ocular prévias e complicações intraoperatórias ou pós-operatórias. Os pacientes foram avaliados após 1, 3 e 6 meses da cirurgia. Foram avaliadas a acuidade visual monocular e binocular para longe, intermediário e perto sob condições fotópica e mesópica, sensibilidade ao contraste monocular sob condições fotópicas, curva de defocus e questionário para avaliação da qualidade de vida. Resultados: A acuidade visual para longe corrigida monocular foi de 0,3 logMAR ou melhor e a acuidade visual para perto com correção para longe foi J3 ou melhor em todos os olhos, sob condições fotópicas. A acuidade visual binocular para perto com a correção para longe foi J1 em todos os casos. A sensibilidade ao contraste estava no nível mínimo de normalidade para frequências espaciais baixas e altas e abaixo dos limites normais para frequência espacial intermediária. O questionário de qualidade de vida mostrou que os pacientes apresentavam altos níveis de satisfação. Conclusão: O implante bilateral da lente intraocular multifocal EyeDiff® proporcionou boa acuidade visual e qualidade de vida, e independência de óculos aos pacientes. A acuidade visual e a sensibilidade ao contraste melhoraram progressivamente entre um e seis meses de pós-operatório.

3.
Indian J Ophthalmol ; 2023 May; 71(5): 2244-2246
Article | IMSEAR | ID: sea-225060

ABSTRACT

We described a modified Yamane technique for simplifying trailing haptic insertion in aphakia correction. In Yamane intrascleral intraocular lens (IOL) implantation technique, trailing haptic implantation is challenging for many surgeons. This modification provides an easier and safer way of trailing haptic insertion into the needle tip and decreases the possibility of bending or breaking the trailing haptic.

4.
Chinese Journal of Experimental Ophthalmology ; (12): 598-602, 2023.
Article in Chinese | WPRIM | ID: wpr-990887

ABSTRACT

Cataract extraction is often combined with the implantation of intraocular lens (IOL) with the diopter matching the operated eye to restore optimal visual function after surgery.However, there are often errors between the actual refractive power of the operated eye and the predicted value.One of the major causes of postoperative refractive error is the change in IOL position compared with the expected position.In order to improve the accuracy of postoperative refraction prediction, Holladay proposed to introduce the concept of effective lens position (ELP) into the IOL diopter calculation formula.The differences in the parameters and algorithms incorporated in the calculation of ELP lead to differences in the accuracy of IOL calculation formulas.With the application of multi-parameter calculation methods, especially the formula based on the artificial intelligence algorithm, the accuracy of IOL calculation formula has been significantly improved.ELP is also affected by various factors such as differences in ocular anatomy, IOL design and material, and surgical procedures, especially the factors affecting the stability of the capsular bag that increase the difficulty of accurately predicting ELP.Therefore, the changes in postoperative ELP need to be further discussed in order to obtain more accurate postoperative refraction.This article aimed to give a review of the development of calculation formulas and the influencing factors of ELP.

5.
Chinese Journal of Experimental Ophthalmology ; (12): 561-567, 2023.
Article in Chinese | WPRIM | ID: wpr-990882

ABSTRACT

Objective:To observe the unfolding status of foldable acrylic intraocular lens (IOL) of different materials, designs and refractive powers implanted in the capsular bag during cataract surgery, and to investigate its influence on the IOL implantation procedure.Methods:An observational case series study was conducted.A total of 1 005 patients who underwent routine phacoemulsification and IOL implantation in Shaanxi Eye Hospital from February to August 2021 were enrolled.The status and unfolding time of the leading haptic, optical region, and trailing haptic of the IOL in the capsular bag and the surgeon were recorded in real-time intraoperative video.Of the 1 005 IOL implants, 681 were hydrophobic, 324 hydrophilic, 733 C-loop, 272 plate-haptic, 909 single-piece, 96 three-piece, 620 preloaded, and 385 non-preloaded.The differences in unconventional implantation factors and IOL unfolding time were compared.The factors influencing IOL implantation status were analyzed by multivariate logistic regression.Multivariate logistic regression was used to analyze the relevant factors affecting IOL implantation status.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Xi'an People's Hospital (Xi'an Fourth Hospital)(No.20200035). Written informed consent was obtained from each subject.Results:There were 14(1.4%) IOLs with unconventional leading haptic status during implantation, including 7 recurved, 4 folded, 2 twisted and 1 straightened.There were 101(10.0%) IOLs with unconventional trailing haptic status during implantation, including 49 stuck in the injector, 40 folded, 10 recurved and 2 broken.There were 22(2.2%) IOLs with overlapped leading and trailing haptic requiring additional separation.There were 4(0.4%) IOLs with reversed optical regions and 2(0.2%) with damaged optical regions.The occurrence rate of unconventional leading haptic status using C-loop IOL was higher than that using plate IOL, and the difference was statistically significant ( P<0.05). The occurrence rate of unconventional trailing haptic status using hydrophilic, non-preloaded, three-piece, and C-loop IOL was higher than that using hydrophobic, preloaded, single-piece, and plate IOL, respectively, and the differences were statistically significant ( χ2=9.100, 61.400, 81.885, 7.587; all at P<0.05). The 22(2.2%) IOLs with overlapped leading and trailing haptic were hydrophobic.The 4 (0.4%) IOLs with reversed optical region were non-preloaded.The results of multivariate logistic regression analysis showed that IOL material, loading method, design and surgeons were related to the unconventional trailing haptic status in implantation ( OR=9.894, 3.720, 6.810, 1.338; all at P<0.05). The average unfolding time of hydrophobic IOL was 26.12(21.21, 30.91)s, which was significantly longer than 3.03(2.16, 4.49)s of hydrophilic IOL ( Z=-25.603, P<0.05). The average unfolding time of C-loop IOL was 25.53(19.41, 30.25)s, which was significantly longer than 2.70(2.08, 3.69) s of plate IOL ( Z=-23.764, P<0.05). Conclusions:A variety of unconventional statuses of IOL can occur during implantation into the lens capsular bag.The use of hydrophobic, preloaded, single-piece, and plate IOLs can reduce the occurrence of unconventional status.The use of hydrophilic IOLs can reduce the overlap of leading and trailing haptic.The use of preloaded IOLs can reduce the occurrence of IOL optical region reversal.The use of hydrophilic and plate IOLs can shorten the operation time.

6.
International Eye Science ; (12): 1499-1502, 2023.
Article in Chinese | WPRIM | ID: wpr-980541

ABSTRACT

Myopia is considered to be a disease occurred under the influence of genetic and environmental factors, and it can only be restored by corrective surgeries. The current surgical methods include laser surgeries and phakic intraocular lens(PIOL)implantation, and PIOL has the advantages of wide range of correction, repeatable procession and small damage to corneal tissue. Furthermore, good visual acuity can be achieved after implantation of intraocular lens. Implantable collamer lens(ICL)is the most common surgical method in this group. The vertical distance between the highest point of the posterior central surface of the implanted lens and the anterior surface of the crystalline lens is called vault. It will cause serious complications if the vault turns out to be abnormal. Up to now, there is no optimal prediction method. This research focuses on vault, discusses the ideal range of postoperative vault, the safety and effectiveness of this surgery, and analyzes the existing prediction methods to provide directions for future clinical research.

7.
Mongolian Medical Sciences ; : 17-21, 2023.
Article in English | WPRIM | ID: wpr-972364

ABSTRACT

Introduction@#Intraocular lens (IOL) implants are monofocal and trifocal lenses which helps to clear up the vision after cataract surgery.@*Goal@#In this work, we aimed to compare the monofocal and trifocal IOL implantation during phacoemulsification surgery.@*Materials and Methods@#This study was conducted on 133 participants. Females comprised n=81, mean n=52 into equal groups. Preoperative and Postoperative cataract surgery UCVA and BCVA were measured and compared during the after 1 day, week 1, 2 weeks and month1. @*Statistical analysis@#The results of the study were processed using the SPSS 25.0 program after coding the data and checking for typographical errors. The normality of the data distribution was tested by inspecting a histogram. Categorical variables were compared using the chi-square test or Fisher's test. Statistical significance was determined at a p-value lower than 0.05@*Ethical statement@#The study was approved by the Research Ethics Committee of the Mongolian National University of Medical Sciences (No.2021/05/21). All patients provided written informed consent before participating in this study.@*Results@#The mean preoperative UCVA was 1.09±0.45D in monofocal IOL group, 0.99±0.49D in trifocal IOL group. At the first week: The mean postoperative UCVA at one week was 0.34±0.29D and 0.27±0.17D, in each group respectively. The mean postoperative BCVA in the first week was 0.28±0.27D and 0.20±0.15D in each group respectively. The mean postoperative UCVA at 1 month was 0.27±0.24D and 0.15±0.16D in each group, while BCVA was 0.26±24.94D and 0.06±0.63D.There was a highly significant statistical difference between the result of UCVA preoperative and the results of UCVA at the early and last postoperative follow up. @*Conclusion@#From our results, the best corrected visual acuity and was better for Trifocal group than Monofocal group. It is evident that post-operative near UCVA and BCVA was statistically significant at monofocal and trifocal groups.

8.
International Eye Science ; (12): 222-227, 2023.
Article in Chinese | WPRIM | ID: wpr-960940

ABSTRACT

Corneal refractive surgery and intraocular collamer lens(ICL)implantation are the mainstream refractive surgery methods at present. Many studies have proved that ICL implantation can effectively improve the postoperative visual acuity of patients. ICL implantation has gained favor among refractive doctors and patients because of its multiple advantages. Excellent postoperative visual acuity and visual quality are the key factors to improve patients' satisfaction. In order to evaluate the subjective and objective visual quality of patients after operation and avoid complications, this article reviews the visual quality and postoperative complications after ICL implantation.

9.
Arq. bras. oftalmol ; 86(5): e20230060, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1513684

ABSTRACT

ABSTRACT A 38-year-old patient who developed aphakia and aniridia secondary to trauma suffered from vision loss. To improve her vision, an iris-intraocular lens complex (Reper®) was fixed to the sclera with Canabrava's double-flanged technique. There was a satisfactory increase in the patient's visual acuity and no complications were observed during the 6-months follow-up. Canabrava technique simplifies and improves the fixation of the iris-intraocular lens complex to the sclera. It is a safe option that does not require scleral flaps or knots.


RESUMO Uma paciente de 38 anos desenvolveu afacia e ani­ridia secundárias a um trauma, levando à perda da visão. Para melhorar sua visão, um complexo de íris e lente intraocular (Reper®) foi fixado à esclera com a técnica de flange duplo de Canabrava. Houve um aumento satisfatório na acuidade visual do paciente e nenhuma complicação foi observada durante o acompanhamento de 6 meses. A técnica de Canabrava simplifica e melhora a fixação do complexo de íris e lente intraocular na esclera. É uma opção segura que não requer retalhos ou pontos esclerais.

10.
Rev. bras. oftalmol ; 81: e0004, 2022. tab, graf
Article in Portuguese | LILACS | ID: biblio-1357124

ABSTRACT

RESUMO A acurácia do cálculo da lente intraocular não é perfeita, podendo ser comuns erros refrativos pós-operatórios, especialmente em pacientes submetidos à cirurgia refrativa prévia ou na presença de córneas assimétricas. O poder corneano após cirurgia refrativa pode ser medido com maior acurácia utilizando o mapa de poder óptico total na zona central de 4mm, com Orbscan II ou pelo mapa equivalent keratometric reading disponível no pentacam, com medidas centrais de 1,0, 2,0, 3,0 e 4,5mm. O objetivo desta série de casos é demonstrar a abordagem de quatro olhos em condições especiais corneanas, por meio do equivalent keratometric reading do pentacam para mensuração do poder corneano e o utilizando na biometria, em comparação com possíveis resultados obtidos com outras estratégias. Os quatro olhos foram submetidos a procedimentos refrativos prévios, e a lente intraocular escolhida a partir do uso do poder corneano calculado pelo equivalent keratometric reading mostrou excelentes resultados pós-operatórios.


ABSTRACT The accuracy of the intraocular lens calculation is not perfect, and postoperative refractive errors are common, especially in patients who have undergone previous refractive surgery or in presence of asymmetric corneas. Corneal power after refractive surgery can be more accurately measured using the total optical power map in the 4-mm central zone, by means of Orbscan II or equivalent keratometric reading map available on pentacam, with central measurements of 1.0, 2.0, 3.0 and 4.5 mm. The purpose of this case series is to demonstrate four approaches performed in special corneal conditions, using pentacam equivalent keratometric reading to measure corneal power and biometrics, and comparing with possible results obtained with other strategies. The four eyes were submitted to previous refractive procedures, and the intraocular lens chosen from the use of the corneal power calculated by equivalent keratometric reading showed excellent postoperative results.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Biometry/methods , Lens Implantation, Intraocular , Refractive Surgical Procedures , Refraction, Ocular/physiology , Refractive Errors/diagnosis , Refractive Errors/physiopathology , Cataract/diagnosis , Visual Acuity , Corneal Topography , Slit Lamp Microscopy , Lenses, Intraocular
11.
International Eye Science ; (12): 1731-1735, 2022.
Article in Chinese | WPRIM | ID: wpr-942851

ABSTRACT

AIM:To observe the early variation trend of the vault after phakic posterior chamber implantable collamer lens/toric implantable collamer lens(ICL/TICL V4c)implantation and analyze the related influencing factors.METHODS:In this retrospective study, a total of 49 patients(98 eyes)who underwent ICL/TICL V4c implantation in the Lanzhou Huaxia Eye Hospital from October 2020 to March 2021 were enrolled. Preoperative ocular biometric parameters were collected, including spherical equivalent(SE), intraocular pressure, axial length, anterior chamber depth(ACD), lens thickness(LT), central corneal thickness, anterior chamber angle(ACA), anterior chamber volume(ACV), white to white corneal diameter(WTW), mean keratometry K1 and K2, and intraoperative implantation size of ICL. The vault was measured by anterior segment optical coherence tomography(AS-OCT)at 1, 3d, 1wk and 1mo after surgery. The patients were divided into insufficient vault group(&#x003C;250μm, 12 eyes), normal vault group(250-750μm, 62 eyes)and excessive vault group(&#x003E;750μm, 24 eyes)according to the vault at 1mo after surgery. The factors affecting the postoperative vault were analyzed.RESULTS:The mean vault values at 1 and 3d, 1wk and 1mo after surgery were 591.05±293.44, 599.62±309.78, 592.22±301.49 and 586.69±285.63μm, respectively. There were significant differences in WTW, ACA, ACV, ACD, ICL size and LT at 1mo after surgery(all P&#x003C;0.05). The regression equation of vault at 1mo after surgery was as follows: vault(μm)=-3142.19+388.25×WTW+10.40×ACA-301.63×LT(R=0.674, R2=0.454, adjusted R2=0.436). WTW had the greatest influence on vault at 1mo after surgery(β=0.47, P&#x003C;0.001), followed by LT(β=-0.34, P&#x003C;0.001)and ACA(β=0.17, P=0.047).CONCLUSION:WTW, ACA and LT were the main factors that affected and predicted the vault at 1mo after ICL/TICL V4c implantation.

12.
International Eye Science ; (12): 818-821, 2022.
Article in Chinese | WPRIM | ID: wpr-923419

ABSTRACT

@#With the continuous progress and development of modern surgical equipment, the types of intraocular lens and the continuous improvement of people's requirements for visual quality, cataract surgery has been transformed from traditional vision restoration surgery into a high-quality and high-demand refractive surgery. Piggyback intraocular lens implantation was originally a new surgical method for clinicians to implant two or more posterior chamber intraocular lenses in patients' eyes to correct hyperopia or secondary correction refractive errors after cataract surgery. With the birth and promotion of functional lenses in recent years, this surgical method has been applied to the field of refractive cataract surgery, which expanded the application of functional intraocular lens and achieved good postoperative effect. This review discusses the development and current clinical application of Piggyback intraocular lens implantation, and further expounds its development trend in the future.

13.
Rev. cuba. oftalmol ; 34(3): e1028, 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1352027

ABSTRACT

Objetivo: Comparar los resultados del implante secundario de lentes intraoculares de cámara anterior rígido con apoyo angular y de lentes intraoculares plegables de cámara posterior suturados a iris, en cuanto a efectividad, seguridad y calidad de vida relacionada con la función visual (cuestionario NEI VFQ-23). Métodos: Se realizó un estudio cuasi experimental de 50 ojos de pacientes afáquicos sin soporte capsular, después de la cirugía de catarata, divididos en dos grupos según el tratamiento. Resultados: Se observó que en el grupo de pacientes tratados con lente intraocular suturado a iris el porcentaje de pacientes con una visión de 20/40 o más fue significativamente superior (96,0 vs. 60,0 , p = 0,000), mientras que los resultados del cuestionario de calidad de vida fueron menores en cuanto a la frecuencia de pacientes con visión de 20/200 o menos (0,0 vs. 16,0 por ciento, p = 0,110); la inducción de astigmatismo, la disminución de la densidad de células endoteliales (361,6 ± 220,5 vs. 556,1 ± 340, p = 0,021) y el porcentaje de pacientes con complicaciones (36,0 vs. 52,0 por ciento, p = 0,254). Conclusiones: Se logran mejores resultados con el implante de lente intraocular plegable suturado a iris(AU)


Objective: Compare the results of secondary implantation of rigid angle-supported intraocular lenses in the anterior chamber versus foldable iris-suture-fixated intraocular lenses in the posterior chamber, in terms of effectiveness, safety and vision-related quality of life (questionnaire NEI VFQ-23). Methods: A quasi-experimental study was conducted of 50 eyes of aphakic patients without capsular support after cataract surgery, who were divided into two groups according to the treatment indicated. Results: It was found that in the group treated with iris-suture-fixated intraocular lens implantation the percentage of patients with 20/40 vision or more was significantly higher (96.0 vs. 60.0 percent, p = 0.000), whereas the results of the quality of life questionnaire were lower in terms of frequency of patients with 20/200 vision or less (0.0 vs. 16.0 percent, p = 0.110), induction of astigmatism, endothelial cell density reduction (361.6 ± 220.5 vs. 556.1 ± 340, p = 0.021) and percentage of patients with complications (36.0 vs 52.0 percent, p = 0.254). Conclusions: Better results were obtained with the implantation of foldable iris-suture-fixated intraocular lenses(AU)


Subject(s)
Humans , Cataract Extraction/methods , Lens Implantation, Intraocular/methods , Endothelial Cells , Anterior Chamber/injuries , Quality of Life
14.
Rev. cuba. oftalmol ; 34(1): e1027, 2021. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1289528

ABSTRACT

Objetivo: Comparar los resultados refractivos del implante secundario de lentes intraoculares rígidos de la cámara anterior con apoyo angular y de lentes intraoculares plegables de la cámara posterior suturados a iris. Métodos: Se realizó un estudio casi experimental con control no equivalente (cohorte histórica). Se estudiaron 50 pacientes (50 ojos) con afaquia e inadecuado soporte capsular después de la cirugía de catarata, a quienes se les realizó implante secundario de lente intraocular con dos técnicas diferentes: lente intraocular en la cámara anterior con apoyo angular (25 ojos) y lente intraocular plegable de la cámara posterior suturado a iris (25 ojos). Resultados: Se observó que en el grupo de pacientes tratados con lente intraocular suturado a iris el porcentaje de pacientes con una visión de 20/40 o más fue significativamente superior (96,0 por ciento vs. 60,0 por ciento, p= 0,000) en los resultados refractivos obtenidos según el grupo de tratamiento. En el grupo A predominaron los pacientes que quedaron emétropes, seguidos de los pacientes miopes. En el grupo B predominaron los pacientes miopes y a diferencia del grupo anterior ningún paciente quedó hipermétrope. Conclusiones: La lente intraocular plegable de la cámara posterior suturada a iris mostró ser más eficaz, indujo menos astigmatismo y fue mejor en la predictibilidad de la esfera en un rango estricto de ± 1,00 dioptrías(AU)


Objective: Compare the refractive results of secondary implantation of rigid angle-supported intraocular lenses in the anterior chamber and foldable iris-suture-fixated intraocular lenses in the posterior chamber. Methods: A quasi-experimental non-equivalent control (historical cohort) study was conducted of 50 patients (50 eyes) with aphakia and inadequate capsular support after cataract surgery, who underwent secondary intraocular lens implantation with two different techniques: angle-supported intraocular lens in the anterior chamber (25 eyes) and foldable iris-suture-fixated intraocular lens in the posterior chamber (25 eyes). Results: In the group treated with iris-suture-fixated intraocular lens implantation the percentage of patients with 20/40 vision or more was significantly higher (96.0 percent vs. 60.0 percent, p= 0.000) in the refractive results obtained for each treatment group. In Group A a predominance was found of emmetropic, followed by myopic patients. In Group B myopic patients prevailed and unlike the other group no patient was hyperopic. Conclusions: Foldable iris-suture-fixated posterior chamber intraocular lenses proved more effective, induced less astigmatism and displayed better sphere predictability in a strict range of ± 1.00 diopters(AU)


Subject(s)
Humans , Aphakia/etiology , Astigmatism/etiology , Lens Implantation, Intraocular/methods , Anterior Chamber/surgery , Cohort Studies
15.
Article in Spanish | LILACS | ID: biblio-1281080

ABSTRACT

Introducción: La cirugía de cataratas tiene como objetivo restablecer la función visual comprometida por la opacificación del cristalino; con el implante del Lente Intraocular se pretende obtener la mejor agudeza visual posible sin corrección adicional. Objetivos: Comparar la exactitud de 8 fórmulas de cálculo de Lentes Intraoculares en la predicción de la refracción postoperatoria con un único dispositivo de biometría óptica en pacientes operados de cirugía de catarata con técnica de facoemulsificación. Materiales y métodos: Serie de casos consecutivos retrospectivos. 100 pacientes fueron sometidos a cirugía de catarata no complicada con de Lente Intraoculares por un único cirujano; del 1 mayo del 2017 al 1 de mayo del 2018; donde la cirugía fue realizada por córnea clara facoemulsificación. En el período preoperatorio todos los pacientes fueron medidos con biometría óptica. La refracción manifiesta se obtuvo al mes de realizada la cirugía. Resultados: La fórmula más precisa y con mejor desempeño general fue PANACEA con un DRA de 0,18 D; cuando consideramos ojos cortos y largos la fórmula Barrett Universal 2 obtuvo menor error de predicción. HAIGIS y LADAS obtuvieron el mejor desempeño en ojos con cámaras estrechas y profundas respectivamente. Conclusión: No se encontraron diferencias en el defecto refractivo absoluto entre las fórmulas tradicionales de tercera generación y las de reciente desarrollo. Algunas fórmulas tuvieron mejor desempeño al considerar ciertas características anatómicas particulares. Es importante personalizar la elección de la fórmula para cada caso específico.


Introduction: Cataract surgery aims to reestablish visual function compromised by lens opacification; Intraocular Lens implantation the aim is to achieve the best visual acuity without additional correction. In recent years, new Intraocular Lens calculation formulas have appeared that could be more accurate than traditional formulas. Objectives: To compare the accuracy of 8 intraocular lens calculation formulas in the prediction of postoperative refraction with a single optical biometry device in patients undergoing cataract surgery with phacoemulsification technique. Materials and methods: Consecutive retrospective case series. Between May 1 2017 and May 1 2018; 100 patients undergo uncomplicated cataract surgery with Intraocular Lens implantation using the phacoemulsification technique. One surgeon did the cases. Optical Biometry was performed using the IOL Master 500 device. Manifest refraction was obtained one month after the surgery. Results: PANACEA was the most accurate formula; with an Absolute Refractive Defect of 0,18 D. When Considering only short and long eyes Barrett Universal 2 got the smallest defect. HAIGIS and LADAS performed better in eyes with narrow and deep anterior chamber respectively. Conclusion: No differences in Absolute Refractive Defect were found between traditional third-generation formulas and those of recent development. Some formulas performed better when considering certain particular anatomical features. It is important to customize the choice of the formula for each specific case.


Subject(s)
Cataract , Cornea , Lens, Crystalline , Biometry , Lenses, Intraocular
16.
International Eye Science ; (12): 1453-1456, 2021.
Article in Chinese | WPRIM | ID: wpr-882111

ABSTRACT

@#AIM: To investigate the therapeutic effect of 23G vitrectomy system used in children with congenital cataracts.<p>METHODS: From November 2017 to December 2018, 11 children(19 eyes)aged 3-8 years old with congenital cataract were recruited in the Department of Ophthalmology, the First Affiliated Hospital of Hainan Medical University. 23G vitrectomy instruments were used to enter the anterior chamber through the incision at the corneal limbus, and complete ring resection of anterior capsule, cataract aspiration, intraocular lens implantation, and ring resection of posterior capsule combined with anterior vitrectomy. The visual acuity, intraocular pressure and ocular conditions of the children were observed during 3-24mo of follow-up.<p>RESULTS: All the surgeries were uneventful. During the surgeries, the anterior chambers were stable, the ring resections of lens capsules were accurate, and the IOLs were implanted at the 1<sup>st</sup> phase. The postoperative visual acuity was significantly improved compared with that before surgery. Only 1 patient had intraocular pressure higher than 25mmHg after surgery, which was controlled within the normal range after medication was given. During the follow-up period, all the children had clear corneas, no anterior chamber hemorrhage, no pupil deformation, the intraocular lens was in the center and the right position, the optic axis was transparent, and no obvious complications occurred.<p>CONCLUSION: The 23G vitrectomy system is safe and effective for the surgery of congenital cataract, it can achieve little trauma, accurate lens capsule resection, little postoperative reaction and few complications.

17.
International Eye Science ; (12): 1047-1050, 2021.
Article in Chinese | WPRIM | ID: wpr-876753

ABSTRACT

@#AIM:To observe the effect of phacoemulsification and intraocular lens(IOL)implantation combined with trabeculectomy on the central anterior chamber depth(ACD)and astigmatism of patients with cataract and glaucoma.<p>METHODS:This prospective study included 100 patients(100 eyes)with cataract and glaucoma who were admitted to the hospital between November 2018 and November 2019. The patients were divided into control group(<i>n</i>=50, 50 eyes)and observation group(<i>n</i>=50, 50 eyes)by the random number table method. The control group was treated with phacoemulsification and IOL implantation, while the observation group was treated with phacoemulsification and IOL implantation combined with trabeculectomy. The LogMAR visual acuity, intraocular pressure(IOP), ACD and astigmatism at 1wk, 2wk and 1mo after operation, visual quality, and the incidence of complications were compared between the two groups. <p>RESULTS:Compared with preoperative, the ACD of the two groups increased, LogMAR visual acuity and IOP decreased at 1wk, 2wk and 1mo after operation(<i>P</i><0.05). Moreover, the ACD of the observation group at 1wk, 2wk and 1mo after operation were higher than those of the control group, and the LogMAR visual acuity, IOP was lower than that of the control group(<i>P</i><0.05). The astigmatism of the two groups increased at 1,2wk after operation, and obseration group decreased at 1mo after operation(<i>P</i><0.05). Meanwhile, the astigmatism of the observation group was lower than that of the control group(<i>P</i><0.05). At 1mo after operation, the scores of watching TV, reading and writing, and fine operation of the observation group were higher than those of the control group(<i>P</i><0.05). The incidence of complications in the observation group was lower than that in the control group(6% <i>vs </i>22%, <i>P</i><0.05). <p>CONCLUSION:Phacoemulsification and IOL implantation combined with trabeculectomy is markedly effective in the treatment of patients with cataract and glaucoma, which can improve vision and visual quality. Lower intraocular pressure and astigmatism, reduce changes in astigmatism, deepen the central anterior chamber depth, and reduce the incidence of complications.

18.
International Eye Science ; (12): 1980-1983, 2021.
Article in Chinese | WPRIM | ID: wpr-887398

ABSTRACT

@#AIM: To analyze the risk factors of corneal edema after phacoemulsification and intraocular lens implantation in patients with cataract. <p>METHODS: The clinical data of 623 patients with cataract(957 eyes)who underwent phacoemulsification and intraocular lens implantation in our hospital between March 2018 and September 2020 were retrospectively analyzed. Patients with corneal edema observed at any time within the first three days after surgery were included in corneal edema group(82 cases, 82 eyes), and patients without corneal edema were enrolled as non-corneal edema group(541 cases, 875 eyes). The preoperative, intraoperative and postoperative related indexes of the two groups were collected and included in Logistic regression model to screen the high-risk factors. <p>RESULTS: Logistics regression analysis showed that age(<i>OR</i>=1.162), Emery lens nuclear hardness grading(<i>OR</i>=1.301)and perfusion time(<i>OR</i>=1.172)were independent risk factors for corneal edema after phacoemulsification and intraocular lens implantation, and the anterior chamber depth(<i>OR</i>=0.651)were independent protective factors avoiding occurrence(<i>P</i><0.05).<p>CONCLUSION:The factors involved in corneal edema after phacoemulsification and intraocular lens implantation are complicated in patients with cataract. It is necessary to be vigilant for high-risk patients in clinical practice and take preventive measures during perioperative period so as to promote rapid recovery of prognosis and visual function.

19.
International Eye Science ; (12): 1535-1538, 2021.
Article in Chinese | WPRIM | ID: wpr-886430

ABSTRACT

@#AIM: To explore the efficacy of phacoemulsification combined with capsular tension ring(CTR)implantation in the treatment of patients with high myopia complicated with cataract, and to analyze its safety. <p>METHODS: A retrospective analysis was performed on the clinical data of 186 patients(186 eyes)with high myopia and cataract who underwent phacoemulsification+ intraocular lens(IOL)implantation treatment in our hospital. Among them, 98 cases(98 eyes)were combined with CTR implantation(combined group)and 88 cases(88 eyes)were not combined with CTR implantation(control group). The best corrected visual acuity(BCVA, LogMAR), visual quality \〖root mean square value(RMS)of higher-order aberration(HOA)\〗 and corneal endothelial cell density were recorded in the two groups before surgery and at 1, 3 and 6mo after surgery, and the area of anterior capsular orifice and inclination angle of IOL were evaluated at 1, 3 and 6mo after surgery, and the occurrence of complications such as postoperative anterior capsule opacification, posterior capsule opacification and capsular contraction syndrome were compared between the two groups.<p>RESULTS: There were interaction effects in the BCVA between the two groups(<i>P</i><0.05). The BCVA of the two groups after surgery was decreased compared with that before surgery(<i>P</i><0.05), and the BCVA of combined group after surgery was lower than that of control group(<i>P</i><0.05). There were interaction effects in the total HOA RMS(<i>P</i><0.05), and the total HOA RMS of the two groups after surgery was increased compared with that before surgery(<i>P</i><0.05), and the total HOA RMS after surgery in combined group was lower than that in control group(<i>P</i><0.05). There were interaction effects in the anterior capsular orifice area after surgery between the two groups(<i>P</i><0.05), and the area in the two groups was decreased with the prolongation of postoperative time(<i>P</i><0.05), and the area in combined group at 3 and 6mo after surgery was higher than that in control group(<i>P</i><0.05). The IOL inclination angle of the two groups had interaction effects between the two groups(<i>P</i><0.05), and the angle of the two groups was increased with the prolongation of postoperative time(<i>P</i><0.05), and the angle of combined group at 3 and 6mo after surgery was lower than that of control group(<i>P</i><0.05). The corneal endothelial cell density in the two groups after surgery was lower than that before surgery(<i>P</i><0.05), but there was no interaction effect(<i>P</i> >0.05).<p>CONCLUSION: Phacoemulsification+ IOL implantation + CTR implantation can improve the visual function of patients with high myopia complicated with cataract, with few postoperative complications and good efficacy and safety.

20.
International Eye Science ; (12): 2141-2144, 2021.
Article in Chinese | WPRIM | ID: wpr-904690

ABSTRACT

@#AIM: To investigate the curative effect of microincision phacoemulsification and ultra-thin artificial lens implantation combined with trabeculectomy in the treatment of age-related cataract complicated with acute primary angle-closure glaucoma(PACG). <p>METHODS: Totally 85 elderly cataract patients(85 eyes)with acute PACG admitted between January 2017 and July 2020 were enrolled. According to the operation method, they were divided into study group(46 cases, 46 eyes)and control group(39 cases, 39 eyes). The control group was treated with 1.8mm microincision phacoemulsification and ultra-thin artificial lens implantation, while the study group was treated with trabeculectomy on the basis of the treatment of control group. The best corrected visual acuity(BCVA), intraocular pressure, anterior chamber angle width classification, corneal endothelial cell count and surgical complications of the two groups were compared. <p>RESULTS: Compared with the same group before operation, the BCVA(LogMAR)of the two groups was significantly reduced at 1, 3 and 6mo after operation(all <i>P</i><0.05), and the study group had lower LogMAR BCVA than the control group(all <i>P</i><0.05). At 1, 3 and 6mo after operation, intraocular pressure of the two groups was significantly reduced(<i>P</i><0.05), and the study group had lower intraocular pressure than the control group(<i>P</i><0.05). Meanwhile, the proportion of anterior chamber angle width grade NⅠwas increased, and the proportion of grade N Ⅳ was reduced in the two groups(<i>P</i><0.05). The proportion of grade NⅠwas higher in the study group than in the control group(<i>P</i><0.05). No significant differences were found between the two groups in terms of corneal endothelial cell count(<i>P</i>>0.05)and the incidence of complications(28% <i>vs</i> 26%; <i>P</i>>0.05). <p>CONCLUSION: For patients with senile cataract complicated with acute PACG, trabeculectomy based on microincision phacoemulsification and ultra-thin artificial lens implantation can significantly lower intraocular pressure, relieve glaucoma, and reduce visual impairment, with little damage to corneal endothelial cells and few complications. Besides, the clinical effect is marked.

SELECTION OF CITATIONS
SEARCH DETAIL